- E-mail: [email protected]
- POffice Add:13th Floor, Building 16, National University Science Park,Zhengzhou,Henan,China
- Factory Add:No. 33 Xinhua Road,Xinmi,Henan,China
The system has high heat utilization rate, convenient operation and maintenance, and closed-loop heating is connected to the atmosphere, which can extend the boiler diesel Burner service life, liquid or gas phase transportation and heating. The heat-conducting oil boiler diesel burner adopts a three-circuit coil design, and the system is equipped with an expansion tank to realize low-pressure and high-temperature heating. The coil structure is adopted, the heating surface is sufficient, and the expansion is completely absorbed. Imported low-NOX burner, full combustion, is an environmentally friendly product. Boiler diesel burner can choose advanced touch screen computer controller and digital computer controller for automatic control. With automatic temperature adjustment, automatic ignition, differential pressure, over temperature, flameout protection. Boiler diesel burner manufacturing specifications are strictly implemented in accordance with national manufacturing standards. Boiler diesel burner cleaning agent is used to clean the heat-conducting oil furnace light oil burner widely used in various industries (petroleum, chemical industry, textile, printing and dyeing, chemical fiber, plastics, building materials, heating), or use heat-conducting oil as heat exchange equipment . Working medium. Scope of application: 1. Used to clean heavy grease, coke and sludge in the heat transfer oil system. 2. Used to clean stubborn heavy oil stains on the surface of mechanical equipment. Product features: 1. Quickly remove the grease and carbon deposits on the internal pipes and heat exchangers of the light oil burner of the heat transfer oil furnace. 2. Neutral, non-toxic, non-corrosive process, the inner tube of the light oil burner of the heat conduction oil furnace and the metal heat transfer surface of the heat exchanger are completely harmless. 3. Quickly dissolve grease and coke, completely dissolve and leave no residue. 4. Easy to use, no need for professional operation, operate according to the operating instructions. 5. Completely environmentally friendly, odorless, non-toxic, non-flammable, non-corrosive, low irritation, no damage to the skin, and can be discharged directly after washing. Cleaning process: draining old oil→pre-washing→cleaning→cleaning→cleaning→cleaning→adding new oil→dehydrating→normal operation method of operation: (1) Draining and removing old oil: the heating system heats the heat transfer oil to 70-80℃, All the heat transfer oil in the system is discharged at the same time. The residual oil in the system can be released as much as possible according to the conditions, and detergents can be added to dilute the oil through permeation, stripping and dissolution, and then drain it out of the system. (2) Pre-washing: the cleaning agent is dissolved at 1.5% of the total circulating water, investment system, fresh water injection system in any part of the heating system, open loop circulating pump, heating furnace to change the water temperature to 60℃+ 5 ℃, for each reactor in the relevant valve of the switch system, each part of the system is circulated separately. After three to five hours, open all low discharge valves in the system and drain the water from the system. (3) Cleaning: Dissolve the cleaning agent according to 4.5~6.5% of the measured total circulating water, put it into the heating system of any part of the system, fill the system with clear water, start the circulation pump cycle, and heat the cleaning agent in the heating furnace to 90℃±5℃. Switch the system valves so that all parts of the system can be cleaned, and the valve switching should be completed every hour. The entire cleaning time shall not be less than 24 hours. (4) Water washing: Fill the system with water, turn on the circulating pump to circulate, use the heating furnace to increase the water temperature to 90℃±5℃, switch the relevant valves in the system, so that all parts of the system can be circulated separately. Flush the system. After three hours, open all the low discharge valves in the system to drain the water in the system. (5) Water washing: Fill the system with water, turn on the circulating pump to circulate, use the heating furnace to increase the water temperature to 90℃±5℃, switch the relevant valves in the system, so that all parts of the system are recycled. Flush the system. After three hours, open all the low discharge valves in the system to drain the water in the system. (6) Water washing: add sufficient clean water to the system, start the circulating pump to circulate, use the heating furnace to increase the water temperature to 90℃±5℃, flush the system, after three hours, open all low sewage valves in the system and discharge the system Of water. After being discharged, the residual water in the system can be purged with compressed air according to the conditions until discharged. (7) Add new oil: inject new heat transfer oil into the system. (8) Dehydration: The dehydration method is equivalent to the dehydration standard before the new system is used. (9) Normal operation: The system is put into normal operation. Correct use of heat transfer oil boiler diesel burner check before starting 1. Check that the heat transfer oil boiler diesel burner and its surroundings are clean and free of debris, check the furnace body, burner, controller, fire hole, chimney channel for normal; 2. Backflow Process equipment and process, check whether the oil level of the expansion tank is higher than 1/4 to 1/2 level, whether the thermometer and pressure gauge are normal; 3. Connect the heating furnace control cabinet power supply, check whether the voltage is normal, check the indicator light and all displays Whether the instrument is normal; 4. Adjust the main pressure reducing valve and the secondary pressure reducing valve to control the pressure at 0.005mpa. ! If you are interested in diesel combustion engines, please contact us for a quote!