- E-mail: [email protected]
- POffice Add:13th Floor, Building 16, National University Science Park,Zhengzhou,Henan,China
- Factory Add:No. 33 Xinhua Road,Xinmi,Henan,China
Because China attaches great importance to environmental protection and production safety, many customers will consider the application of heat transfer oil for electric heaters Heating furnace replaces heating furnace. Electric heater heat conduction oil boiler diesel burner is the energy conversion equipment of this kind of electric engineering drive. It heats high temperature heat conduction oil according to electronic components, so as to realize reasonable heat transfer. Its driving force drive advantages also make it popular in the sales market, but people do not master its power consumption. So, where is the electricity consumption of the electric heating oil heating furnace? Will it lead to extravagance and waste? Let's take a look at the calculation of the power consumption of the electric heater's heat-conducting oil boiler diesel burner: take a 65kw oil furnace as an example. (1) The pump output power is 5.8Kw, the set temperature is exceeded within 1 hour, and it operates for 8 hours a day. (2) Temperature control: Maintain temperature balance. In the intermittent operation of the heating tube of the electric heating oil furnace, it generally accounts for 30% of the total output power, 16kw per hour. This statistical data is related to the heating tube, the application of the natural environment, and the heat dissipation standard of the heat pipe. The greater the heating capacity. The specific power consumption is huge. (3) Circulating water pump: pump output power is 5.8KW, 8 hours power consumption is 46KW. It can be calculated that the daily power consumption of the electric heating oil furnace is 278KW. Based on the specific electricity charges, the basic daily electricity cost can be calculated. According to the left and right calculations, it can be seen that if the electric heater type heat conduction oil boiler diesel burner is to save electricity, it can be dealt with in the following ways: (1) If economic development permits, it is recommended to use thyristor to operate the electric heating tube to reduce the power Operate at the lowest standard. (2) Abrasive tool temperature AC contactor often touches the impact of the power grid. It is recommended to use intermediate relay or thyristor to operate. (3) Improve the high efficiency of the heating pipe and reduce the heating time. (4) Reduce the heat dissipation of the heat pipe and prevent the extravagant waste of heat. (5) Try to avoid the output power of the circulating water pump. Choose the electric heater and heat conduction oil heating furnace as the heat conduction oil heating furnace. Electromagnetic energy is used as a heating method, and the actual operation and maintenance are simple, convenient and low-cost. Its key operating cost lies in its power engineering costs and applications. How much electricity does the electric heater heat conduction oil heating furnace use? Does the electric heater heat conduction oil boiler diesel burner consume more power? The electromagnetic energy of the electric heater heat conduction oil heating furnace is mainly used for heating and maintaining the circulation system of the pump, so the output power consumption is the addition of the output power consumption of the heating section and the circulating water pump. How to measure the power consumption of electric heaters and heat-conducting oil heating furnaces? Take a 180kw electric heater thermal oil boiler diesel burner as an example, the pump output power is 6.5kw, and it operates for 12 hours a day. Operation at full output power for 1 hour exceeds the operating temperature, the power consumption is 180 degrees, and then the temperature is balanced, the heating tube of the electric heater, heat transfer oil, boiler, diesel burner, and the heating pipe of the total output power generally account for 20%-30% of the total output power every time The hour is 46kw. This statistical data and the application of the natural environment are related to the heat pipe heat dissipation standard. The greater the heating capacity, the greater the specific electricity consumption. On the other hand, the power consumption of the pump is 70kWh, and the power consumption of the electric heater heat transfer oil boiler diesel burner can be estimated to be 765kWh per day. Based on the specific electricity charges, the basic daily electricity cost can be calculated. The thermal efficiency of the electric heater heat-conducting oil heating furnace reaches about 95%, and the electricity consumption is not easy to cause extravagance and waste. This is the company's way to save costs. There are many ways to reduce the energy consumption of electric heaters and heat-conducting oil heating furnaces, such as heat preservation pipe solutions, heat preservation pipes and so on. Certain countermeasures can also greatly reduce the energy consumption of the electric heater heat conduction oil heating furnace. The key to the electric heater, heat-conducting oil boiler and diesel burner is two power-consuming components, one is a circulating water pump, and the other is an electric heating tube. The electric heater heat conduction oil heating furnace consumes more output power during the whole heating process. After this temperature is exceeded, in all normal production and manufacturing in the middle and late stages, the heating part of the heat-conducting oil heating furnace only has the temperature control function, and the energy consumption is also greatly reduced. When the heat-conducting oil electric heating furnace is in temperature control, the circulating water pump is in operation from beginning to end. For example, the output power of the pump is 5kw, the power is 5kw/h, the output power of the heating tube is 65kw, and its power is only 1/3~1/2 of the output power of the electric heating tube. For manufacturing industries with low heat consumption and lower temperature, the specific heat consumption of the high-temperature heat conduction oil heating furnace is lower. If economic development permits, it is proposed to use thyristor to operate the electric heating tube to maintain the power at a minimum standard. On the other hand, the AC contactor of the electric heater and the heat-conducting oil boiler diesel burner often touches the impact of the power grid. It is recommended to use an intermediate relay or a thyristor to operate. ! If you are interested in diesel combustion engines, please contact us for a quote!