- E-mail: [email protected]
- POffice Add:13th Floor, Building 16, National University Science Park,Zhengzhou,Henan,China
- Factory Add:No. 33 Xinhua Road,Xinmi,Henan,China
Today we mainly understand the various causes of various hidden dangers under the thermal oil boiler diesel burner. Since the thermal oil boiler diesel combustion engine has been widely used in various productions, it provides a lot of comfort for people's lives, so you need to be more careful when using it, otherwise it will bring great safety hazards. From the practical application point of view, the thermal oil boiler diesel burner is also a kind of industrial equipment with a high risk factor, especially under certain specific working conditions. For example, some manufacturers of thermal oil boiler diesel burners do not have boiler diesel burner manufacturing licenses for the production of thermal oil boiler diesel burner products. Therefore, the production quality of thermal oil boiler diesel combustion products is not satisfactory. If this type of equipment is selected and put into use by consumers, it is easy to cause some unnecessary safety accidents, which will cause great harm. Secondly, if the organic heat carrier of the thermal oil boiler diesel combustion engine deteriorates, it is easy to cause safety accidents. Once the liquid phase forced circulation heat carrier furnace is aging, it will cause the heating surface of the heat transfer oil boiler diesel burner to overheat and the tube to explode, and may even cause a fire accident, which will bring people a great economic loss. In addition, the thermal oil boiler diesel burner supporting the circulating pump is also very critical. If it is not suitable, the equipment will have many failures during operation, and it is also very likely to cause serious damage to the thermal oil boiler diesel burner equipment, thereby causing operators to The personal safety will also pose a serious threat. In addition, the focus of the inspection is the flange connection of the heat-conducting oil boiler diesel burner, welding quality or sealing problems, these deficiencies may also cause fire or poisoning accidents. In order to avoid serious accidents, you should be very careful in all the above aspects. Precautions for inspection and maintenance of heat-conducting oil boiler light oil burner 1. The heat-conducting oil boiler diesel burner should be firmly installed on a stable foundation or base, the oil drain groove should be cleared, and the cooling air circulation should be stable. The foundation is unreliable, vibration and noise may be generated during operation, and the bearings and gears may be damaged. When the transmission connection is protruding or when gears or sprocket are used for transmission, a protection device should be considered. When the output bearing is subjected to a large radial load, a reinforced type should be selected. 2. Install the equipment as required to ensure that the staff can easily access the mimeograph, air plug and oil drain plug. After installation, check the accuracy of the installation position and the compression reliability of each fastener in order. The fasteners should be able to rotate flexibly after installation. The reducer is lubricated by a splash oil pool. Before operation, the user should remove the screw plug of the air hole and replace it with an air plug. According to different installation positions, open the oil level plug screw and check the height of the oil level line. Add oil from the oil level plug until the oil overflows from the oil level plug hole. Only when the oil level plug is properly fixed can the no-load test run for no less than 2 hours. The operation should be stable, without impact, vibration, noise and oil leakage, and abnormalities should be eliminated in time. After a period of time, the oil level should be checked again to prevent possible shell leakage. For example, when the ambient temperature is too high or too low, the lubricant level can be changed. 3. When installing the heat-conducting oil boiler diesel burner, attention should be paid to the centering of the transmission center shaft, and the error should not be greater than the compensation amount of the coupling used. Good alignment can prolong the service life and obtain the ideal transmission efficiency. 4. When installing the transmission parts on the output shaft, it is not allowed to hit the transmission parts with a hammer. Generally, the internal thread of the assembly fixture and the shaft end is used to squeeze the transmission parts with bolts, otherwise the internal parts of the heat transfer oil furnace and light oil burner may be damaged. It is best not to use rigid fixed couplings, because improper installation of such couplings will cause unnecessary external loads, resulting in early damage to the bearings, and even serious breakage of the output shaft. ! If you are interested in diesel combustion engines, please contact us for a quote!