- E-mail: [email protected]
- POffice Add:13th Floor, Building 16, National University Science Park,Zhengzhou,Henan,China
- Factory Add:No. 33 Xinhua Road,Xinmi,Henan,China
High performance liquid phase heat transfer oil has the characteristics of bottom pressure and high temperature work, and its heating temperature reaches 410 in the high performance liquid phase °C, the vapor phase reaches 350°C. High-efficiency liquid-phase heat transfer oil can be used in all manufacturing places where the heating temperature of the processing technology is uniform and stable, and the flame is not allowed to be heated immediately between 130°C and 220°C. The genetic Rally uses coal, oil and steam as raw materials, and high-temperature heat-conducting oil as the material. The hot oil circulation gasoline pump uses the compulsory substance to carry out the high-efficiency liquid-phase circulation system, and the energy is transferred to the thermal machinery and equipment, and then returned to the hot blast stove for heating again. The high operating temperature is maintained during the actual operation of the bottom pressure and high-precision manipulation materials. The system software has a high heat utilization rate, and the actual operation and maintenance are convenient. It is an ideal heater with safety, high efficiency, environmental protection and energy saving. Characteristics: (1) Get the bottom pressure high temperature heat medium, which is convenient to adjust, and the heating is symmetrical, which can consider the temperature of precision machining. (2) The high-efficiency liquid phase circulation system is heated without condensation heat damage, and the heating system software has high thermal efficiency. (3) The substance reacts exothermously when exposed to heat during work, and the temperature changes to the elevator with the volume. The system software has technical countermeasures for compensation. (4) Technical countermeasures to strictly control the water content of low volatile organic compounds such as gases and moisture in the working substances of the circulation system before heating. Application: Chemical-oil organic chemistry, polymer industrial production, reaction tank, steam distillation, extraction. Plastic industry-plastic gun, extrusion processing. Cotton textile-epoxy resin setting machine, dyeing machine, drying room, high temperature machine, drum machine. Industrial production of vulcanized rubber-heating of vulcanized rubber. Food industry-cooking, drying, edible oil refinement. Catalpa--heating and installation of straight hair splint, foam board and plywood. Paper industry-double-layer cardboard packaging, dry, dry. Others-heating of metal material plating solution, cold coating, dryness, steam distillation, restoration, extraction, drying, etc. A large number of automobile fuel tanks are also called high-rise automobile fuel tanks. The key functions are given: 1. High-efficiency liquid phase high-temperature heat-conducting oil swells and closes, high-temperature heat-conducting oil heats up, and unnecessary high-temperature heat-conducting oil returns to a large number of tanks according to the expansion tube; 2. The air pipe is discharged to a large number of tanks through the oil separator, and discharged to the environmental factors through a large number of tanks; 3. There is some cold oil in a large number of tanks, which has the effect of skeleton sealing, so that the high-temperature heat transfer oil circulation system pipeline becomes a closed Type of respiratory system. In the high-efficiency liquid phase heat transfer oil, a large number of water storage tanks are indispensable machinery and equipment. It is located in the largest part of the heating equipment system software to ensure the condition of the level gauge during normal operation. 1. Therefore, the system software or the remaining oil filled by the high temperature heat transfer oil caused by volatilization and actual operation are introduced; 2. The system alignment increases the light multi-component in the oil and the residual small amount of water at high temperature in the system software and low heating furnace The vaporization of the chemical substances generated by the gasification takes time; 3. The immediate contact between the gas and the high temperature heat transfer oil ensures that the high temperature heat transfer oil is not oxidized by the high temperature air, and increases the service life of the high temperature heat transfer oil; 4. Increase and stabilize the working pressure of the high-temperature heat transfer oil in the system software to ensure the safe operation of the high-efficiency liquid phase of the system, and the circulation system is all normal; 5. In the event of a sudden power failure or other emergency situation, turn off the heater gate valve and open a large number of tank gate valves. Let a large amount of cold oil in the tank replace the boiling oil in the furnace, so that the heater can be maintained and the oil slick S will not exceed the temperature; the N2 sealing equipment must be improved here. Commercial characteristics of gasoline and diesel heat transfer oil: 1. Under lower pressure, higher operating temperature can be obtained. 2. The heating is stable and the temperature is accurate. 3. Under different load levels, the thermal efficiency can be maintained at an excellent level. 4. High-efficiency liquid phase transportation energy is a kind of heat carrier whose saturated vapor pressure is less than 75 times that of water at 400℃. 5. With detailed real-time control and safety protection equipment. Gasoline and diesel heat transfer oil characteristics: 1. It has the characteristics of bottom pressure, high temperature, safety, high efficiency, environmental protection and energy saving. 2. Equipped with sound real-time control and safety precaution equipment, which can accurately manipulate the operating temperature. 3. Reasonable configuration, complete supporting facilities, short installation period, convenient actual operation and maintenance, and convenient layout of heating furnace. 4. Because the electric heating organic heat carrier furnace adopts the explosion-proof structure, it can be used in the explosion-proof type of the second industrial zone, and the explosion-proof level can exceed the C level. Gasoline and diesel heat conduction oil start-up inspection: 1. Is the hot blast stove and the surrounding environment clean and free of dirt, whether the furnace wall, burner, control board, fire hole, chimney, etc. are all normal; 2. Reversal technology and processing technology, Check whether the oil level in the expansion tank is higher than the 1/4-1/2 level gauge, thermometer, barometer, etc. whether everything is normal; 3. Turn on the switch power supply of the hot blast stove control box and check whether the working voltage is normal. Check whether the display lights and the display instruments are normal; 4. Adjust the main pressure regulating valve of natural gas and the second pressure regulating valve to control the working pressure at 0.005Mpa. Gasoline and diesel heat transfer oil cleaning method: In the production practice, the thickness of coke is below 2mm is safe, and the coke layer in the furnace body is between 0 and 1.6mm. At this time, the continuous deposition of the coke layer and the melting amount of a heat carrier are roughly balanced. The thickness of the coke layer in the furnace body can be accurately measured with an ultrasonic thickness gauge. A filter device should be installed in the circulating water pump to filter out floating high polymers caused by chemical reactions and some over-temperature carbon particles. The filter device should be convenient for disassembly, assembly, and replacement, so as to remove residues and residues on time to ensure the actual effect of filtering. ! If you are interested in diesel combustion engines, please contact us for a quote!