What if the burner fails to ignite?

2021-01-18 00:00


If it is an ignition failure, how to judge first, start the burner three times first, if it does not ignite the combustion, it is judged as an ignition failure, and corresponding inspections are required to eliminate the failure. The fan runs normally during ignition and the program is correct. 1. If it is a gas source failure, check whether the natural gas pressure is normally maintained at 3-5kpa. If it is too high or too low, it will not ignite. Treatment method (adjust natural gas pressure regulation, pressure setting). 2. If the damper fails, please check the size of the damper. When the damper is too large, it may easily ignite multiple times. Use treatment methods. (The damper should be appropriately adjusted to be very small, but not completely closed). 3. If the ignition electrode or the ignition transformer fails, the ignition transformer does not ignite, or the ignition electrode is too dirty, an ignition failure will occur. Treatment method (test whether the ignition transformer is ignited, clean the ignition electrode, adjust the ignition gap to keep 2-3mm). To If you are interested in gas oil burners, please contact us for a quote!