Home > News >

How to repair the smoke from biomass pellet burner?

2021-01-18 00:00


To The maintenance of the biomass pellet burner needs to understand the failure of the burner first. Below we introduce what is the fault of the biomass pellet burner smoking. We should first consider whether the burner components are intact. Under the premise, we are considering the following aspects to carry out the corresponding maintenance of the burner: To 1. Adjust the proper oil pressure and damper angle. Note: If you are not very sure, do not adjust the pressure and angle at a large angle. To 2. Check the exhaust system of the combustion chamber, chimney, etc., and observe whether there is grease stain with naked eyes. In the case of high temperature, the volatilization of grease is one of the important reasons for black smoke. To If the above two steps are still ineffective, perform the following tasks: check the filter, including the external filter, oil pump filter (inside the oil pump), and nozzle filter. Check the oil pump pressure and adjust it appropriately. If the pressure is lower than 1Mpa, most of the oil pumps need to be replaced. For burners with a solenoid valve at the front, check whether there is debris in the solenoid valve, causing insufficient fuel supply. If necessary, the burner can be disassembled to observe the fuel injection status. The oil pump pressure is regulated normally, and most of the oil nozzles can be used, but it is recommended to replace the oil nozzle once a year—even if the nozzle wear does not affect the use, the combustion efficiency continues to decrease with the degree of wear. In the case where all the above investigations have been completed, and no fault source has been found, it is necessary to hire personnel with professional experience to recheck the air-fuel ratio. Smoke from the burner is simple to say, just adjust the oil pressure of the air valve to solve it. But in fact, it involves the core combustion technology of the burner, so it is quite complicated. Some of the smoke failures of the burner can not be solved by professionals, and can only be dealt with by replacing the parts. To If you are interested in gas oil burners, please contact us for a quote!

  • BNG250/300/350P/FC Gas Burner

  • BNH40/60 G Heavy Oil Burner

  • BNH 75/100/120 F Heavy Oil Burner

  • BNL40/55 P/FC Diesel Light Oil Burner

  • BNL120/180/250 P/FC Light Oil Burner

  • BNL75/100 P/FC Light Oil Burner

  • BNG28P gas burners

  • BNH 180/250/300 F Heavy Oil Burner

Inquiry For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.
Name:
Whatsapp:
* E-mail:
Product:
* Message:
Click on the button to verify