Home > News >

What is the reason for the large pressure difference of the heat-conducting oil boiler diesel burner?

2021-01-08 00:00


The pressure difference indicates the flow rate of the heat transfer oil in the pipeline of the boiler diesel burner. The pressure difference is large and the flow rate is fast. However, if the pressure difference is too large, the pipeline will be blocked; if the pressure difference is too small, the flow rate will be low. Under normal circumstances, the pressure difference should not be less than 0.5, not more than 2.5. Of course, the inlet pressure is high, the outlet pressure is low, and the pressure difference, the heat transfer oil can be from the inlet to the outlet, how simple. Stable and normal pressure difference is the first element to ensure the safe operation of hot oil boiler diesel burners. As long as the pressure difference is normal, the boiler diesel burner will not have major safety accidents. Remember, remember, safety first, pressure Short of first. In the heat-conducting oil furnace light oil burner, what should be the treatment of the oil outlet, so better? Moreover, what is the pressure difference between its inlet and outlet? In addition, on this kind of boiler diesel combustion engine, there will be any questions or doubts, we do not know and understand? All of these are related to the light oil burner of the thermal oil furnace. So, let's take a look at it so that we can resolve any confusion. 1. What should be done with the oil outlet of the heat-conducting oil burner light oil burner? What is the general pressure difference between its inlet and outlet? The oil outlet in the light oil burner of the heat conduction oil furnace should generally be sealed to avoid problems such as leakage. As for the difference between the inlet and outlet pressures, if the heat transfer oil furnace light oil burner is between 6 and 6 million CAL, it is usually in the range of 0.2-0.3 MPa. 2. What is the role of the circulating pump in the circulating system of the light oil burner of the heat transfer oil furnace? In the circulation system of the heat-conducting oil furnace light oil burner, the main function of the circulation pump is to provide enough power for the system to make the circulation system work normally. It is an important part because if it is abnormal, it will affect the circulatory system. Therefore, we should not be negligent, should not take it lightly, and should avoid problems. 3. What are the functions of the high and low grooves in the light oil burner of the thermal oil furnace? In the light oil burner of the electric heat conduction oil furnace, it must have a low groove and a high groove, because they play an important role, so they cannot be omitted. For the lower tank, its main function is to store oil. For the high slot, it has two main functions, especially: Function 1: Provide enough heat transfer oil for the circulating pipe to avoid interruption and adverse effects. Function 2: During the heat transfer oil heating cycle, the air and water vapor in the pipeline can be discharged from the system through the high water tank. In addition, due to thermal expansion and cold contraction, the excess heat transfer oil can be returned to the high groove through the expansion tube, thereby avoiding the waste of heat transfer oil. Matters needing attention 1. For the oil and gas heat carrier boiler diesel burner using heat transfer oil as the heat carrier, the system should be equipped with an expansion tank, a water storage tank, safety components, measuring instruments and control devices. 2. When the heat transfer oil is put into use, start the circulating oil pump during the running phase, and start ignition and heating after running for half an hour. When using for the first time, the temperature should rise slowly, about 20℃ per hour. When the temperature rises to 180~200℃, the temperature should be kept for a period of time before normal use. 3. When using, check carefully and strictly prevent the leakage of water, acid, alkali and low boiling point substances into the use system. The system should be equipped with a filter device to prevent all kinds of debris from entering and to ensure the purity of the oil. 4. After six months of use, oil analysis should be performed. If poor heat transfer or other abnormal conditions are found after long-term use, the oil should be analyzed, added or replaced according to the analysis results. Standard dosage: basic carbon must not be greater than 1.0%, acid value must not be greater than 0.5mgK(OH)/g, ignition point change must not be less than 20%, viscosity change must not be greater than 10%, and the new oil should be replaced. 5. In order to ensure the normal service life and heat conduction effect of heat transfer oil, it is strictly prohibited to use over temperature. The design and installation of the heating system of the heat-conducting oil burner light oil burner shall strictly follow the design rules of the heat-conducting oil burner light oil burner formulated by the relevant state departments to ensure the safe operation of the system. Equipment risk analysis 1, general chaos, employee injury, minor economic loss. 2. The staff suffered severe interference, minor injuries, severe casualties, and heavy economic losses. 3. Major, especially major chaos, group injuries, especially major economic losses. ! If you are interested in diesel combustion engines, please contact us for a quote!

  • BNH350/600 F Heavy Oil Burner

  • BNG50/60P Gas Burner

  • BNG35P/FC gas burner

  • BNG85/120P/FC Gas Burner

  • BNH40/60 G Heavy Oil Burner

  • BNL300/350/600 P/FC diesel oil Burner

  • BNH 180/250/300 F Heavy Oil Burner

  • BNG150/210P/FC Gas Burner

Inquiry For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.
Name:
Whatsapp:
* E-mail:
Product:
* Message:
Click on the button to verify