Home > News >

Emergency measures for gas heat conduction oil boiler diesel burners

2021-01-08 00:00


For gas-fired heat-conducting oil boiler diesel burner, learning and understanding of this kind of heat-conducting oil boiler light oil burner It has already started before, so that we can be timely and have a firm grasp. So, based on this, and in order to promote the learning process, the following will continue so that we have certain gains and inspiration. The failure of the light oil burner of the gas heat conduction oil furnace. Problem 1: The furnace does not burn. For the failure of the light oil burner of this gas heat conduction oil furnace, it involves many aspects and reasons, so the following is a detailed description. Aspect 1: The specific reason for natural gas is that there is a blockage in the gas pipeline, or there is a problem with the ignition solenoid valve, and there may be a problem with its control line. For its inspection, it is: remove the ignition solenoid valve, and then energize. When the solenoid valve moves backward, the valve core opens to check whether the ignition gas is normal. In this way, the malfunction of the gas and ignition solenoid valve can be eliminated. Aspect 2: The main reason for ignition is the problem of the ignition electrode control circuit or the insufficient sensitivity of the ignition electrode probe. Its detection method is to use a multimeter to detect whether it has an open circuit, etc. In addition, determine whether it is due to the rupture of the ignition electrode scale, so that the gas heat transfer oil burner light oil burner has no ignition signal. As for the solution, it is very simple. Break the circuit and take concrete and effective measures to solve it. Problem 2: Failure of the diesel burner of the gas heat transfer oil boiler. If the diesel burner of the gas heat transfer oil boiler does not work normally, there are three main reasons: the installation position of the flame detector is incorrect or it is not working properly. Moreover, the flame plate is not in the correct position, and the air to gas ratio is not appropriate. There are three main reasons. Therefore, in view of the above reasons, corresponding measures have been taken to effectively solve the problem, so that the light oil burner of the gas heat conduction oil furnace can be restored to normal. There are many accidents of gas heat conduction oil furnace light oil burner or oil heat conduction oil furnace light oil burner accident. Coal-fired steam or hot water boiler diesel burner accidents may also have special accidents. Such accidents usually include furnace and flue Explosion accidents, etc. The accident happened. Furnace and flue are common accidents of light oil burner of gas heat conduction oil furnace and light oil burner of fuel heat conduction oil furnace. In severe cases, the furnace wall collapses, the bricks fly up, the roof and flue are opened, flames and high-temperature smoke are sprayed out, which may cause casualties. Through the analysis of some accident cases at home and abroad, it is found that the explosion phenomenon in the furnace and flue generally has the following types: the pressure in the furnace (negative pressure to positive pressure) increases sharply; explosion-proof doors, furnace doors, and fire holes. Fireworks spurted from inspection holes and other places; they made dull or loud noises. Once the above phenomenon occurs, most of the light oil burners or flues of heat-conducting oil furnaces produce an explosion warning, and the operators should be dealt with in time or evacuated. As we all know, the thermal oil boiler diesel burner can operate normally under normal standard operation. Sometimes, the cause of furnace and flue explosion is due to irregular operation. The following is a list of some irregular common operation behaviors for your reference: 1. Before the ignition of the thermal oil boiler diesel burner, the combustible gas remaining in the furnace cavity is not removed, there is no ignition program control device, or the operation rules are not implemented, and the ignition is blind. 2. The heat transfer oil boiler diesel burner suddenly goes out during operation, even if the fuel supply is not interrupted; 3. When the oil supply of the heat transfer oil boiler light oil burner is interrupted due to the failure of the fuel supply pump, only the heat transfer oil boiler diesel burner The main valve is not closed tightly. When the fuel supply pump returns to normal, a large amount of fuel is injected into the furnace; 4. When the circuit is cut off, the guide rail, blower and fuel pump stop at the same time. The power switch will not turn on immediately. Emergency measures should be taken after the furnace and flue explode. The furnace should be shut down immediately, and the power, oil or gas source should be cut off at the same time to prevent the accident from further expanding, and then adjust the water level of the boiler diesel burner to normal, and then in a safe environment Inspection of the light oil burner of the heat transfer oil furnace where the furnace and flue explosion occurred. The stoker must strictly follow the operating rules. Regardless of the first ignition before the gas or oil heat transfer oil burner light oil burner starts, or the re-ignition after the heat transfer oil burner light oil burner stops during operation, the ignition operation procedure must be followed. ! If you are interested in diesel combustion engines, please contact us for a quote!

  • BNH 75/100/120 F Heavy Oil Burner

  • BNG35P/FC gas burner

  • BNL40/55 P/FC Diesel Light Oil Burner

  • BNG150/210P/FC Gas Burner

  • BNL18/26/35 DSG Light Oil Burner

  • BNG400FC/600FC Gas Burner

  • BNL14/DSG Light Oil Burner

  • BNH350/600 F Heavy Oil Burner

Inquiry For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.
Name:
Whatsapp:
* E-mail:
Product:
* Message:
Click on the button to verify