1, the heat oil boiler diesel burner hot oil outlet temperature display: it can be displayed on site and transmitted to the control cabinet for The meter further displays. The user can set the temperature value and can be interlocked with the induced draft fan to realize automatic adjustment operation and high temperature alarm. 2. Heat conduction oil boiler diesel burner heat conduction oil inlet temperature display: it can be displayed on site and sent to the control cabinet for instrument display. 3. Display of heat conduction oil outlet pressure of heat conduction oil furnace and light oil burner: it can be displayed on site and sent to the control cabinet for further display, which can realize overpressure alarm. 4. The pressure display of the heat conduction oil inlet of the heat conduction oil boiler diesel burner: it can be displayed on site and sent to the control cabinet for instrument display. 5. Control the liquid level of the expansion water tank of the thermal oil boiler diesel burner: realize the alarm of low expansion water tank level, promptly remind the stoker to refuel the system, and ensure the safe and reliable operation of the boiler diesel burner system. Manual firing (fixed) grate vertical coal-fired organic heat carrier furnace product functions 1. The thermal oil boiler diesel burner is a direct-flow boiler diesel burner based on the design concept of forced circulation. 2. Closed cycle heating, connected to the atmosphere, can extend the service life of the boiler diesel burner, transfer heat energy in the liquid phase, reduce heat loss, significant energy saving effect, and good environmental protection effect. 3. The heat-conducting oil boiler diesel burner adopts a three-ring coil design, which determines the safety of the traditional boiler diesel burner. 4. Due to the coil structure, the heating surface is enough to make it have higher thermal efficiency. 5. The heat transfer oil boiler diesel burner is characterized by countercurrent heat transfer, and the temperature difference between the combustion flue gas discharge temperature and the heat transfer oil outlet temperature is less than 30°C. 6. The heat-conducting oil boiler diesel combustion engine has excellent structure, mainly working under low pressure, so that the working temperature is lower than 450℃, and it has the characteristics of low pressure and high temperature. Functional characteristics 1. Low pressure, high temperature, safety, high efficiency and energy saving. 2. It has a complete operation control and safety monitoring device, which can accurately control the working temperature. 3. Reasonable structure, complete supporting facilities, short installation period, convenient operation and maintenance, and convenient layout of boiler diesel burner. 4. Because the organic heat carrier furnace adopts advanced explosion-proof electric heating structure, it can be applied to factory II explosion-proof, and the explosion-proof grade can reach C level. Other functions Compared with the traditional heat transfer medium water and steam, heat transfer oil has the following characteristics: 1. High working temperature can be obtained under almost normal pressure. It can greatly reduce the working pressure and safety requirements of the high-temperature heating system, and improve the reliability of the system and equipment. 2. It can meet the process requirements of heating and cooling at different temperatures in a wide temperature range, or realize the process requirements of high temperature heating and low temperature cooling of the same heat transfer oil in the same system. The complexity of the system and operation can be reduced. 3. The water treatment system and equipment are omitted, the thermal efficiency of the system is improved, and the maintenance workload of equipment and pipelines is reduced. It can reduce the initial investment and operating costs of the heating system. 4. If the system leaks due to an accident, the heat transfer oil and open flame may burn when encountered. This is the problem of the heat transfer oil system compared with the steam system. However, in the absence of leakage, since the thermal oil system works at low pressure, the operational safety of the thermal oil system is higher than that of the water and steam system. 5. Compared with the molten salt of another high temperature heat transfer medium, when the working temperature is higher than 400℃, molten salt has absolute advantages over hot oil in terms of the price and service life of the heat transfer medium, but it has other aspects There are obvious shortcomings, especially in the complexity of system operation. 6. Advanced technological process, organic heat carrier boiler diesel burner is a new type of special heating boiler diesel burner, with the characteristics of high temperature and low pressure, working pressure is 0.1 Mpa, even if it is atmospheric heating temperature, liquid 340℃ or 400℃ In the gas phase, the overall structure has a certain degree of flexibility, and considering the free expansion operation of the heating components, the tubular heating surface of the elbow plate, in order to operate more safely and efficiently, an air preheater is added to enhance the combustion degree in the furnace. Speed will increase in various industries to improve efficiency, environmental protection, and energy-saving services. ! If you are interested in diesel combustion engines, please contact us for a quote!