Home > News >

Maintenance plan for heat conduction oil boiler diesel burner

2021-01-08 00:00


With the development of industrial production and the advancement of science and technology, electric heating and heat transfer oil boiler diesel burners have been continuously developed and applied. Although the working pressure of the diesel burner of the electric heat transfer oil boiler is lower, the temperature of the heat transfer fluid in the furnace is higher, and most of them are flammable and explosive. Once leakage occurs, it will cause fires, explosions and other accidents, and even cause casualties and property losses. Therefore, we must attach great importance to the safe operation and management of the diesel burner of the electric heating oil boiler. Recently, many customers have inquired: How to maintain the diesel burner of the electric heating heat transfer oil boiler during normal use? As a high-quality heating equipment, the maintenance work of the diesel burner of the electric heating heat transfer oil boiler is particularly important. No matter what kind of equipment, maintenance and maintenance are very important tasks. The heating equipment engineer mainly summarizes the following maintenance methods: (1) The electrical control cabinet should avoid dust accumulation, and often use compressed air to blow it out to ensure good electrical contact . (2) The heat transfer oil in the heat transfer oil boiler diesel burner shall not exceed the maximum allowable temperature. In order to ensure the quality of heat transfer oil and strictly control the performance indicators of the organic heat carrier, first open the exhaust valve in the organic heat carrier furnace to remove the air, water and organic heat carrier mixed steam from the diesel burner of the electric heating heat transfer oil boiler. Generally, after half a year of use every 3 to 6 months, the heat transfer oil samples will be tested once, and pay attention to not mixing different oil products. (3) The thermometer should be checked frequently for the diesel burner of the electric heating heat transfer oil boiler, and regular measurement should be carried out to prevent the thermal resistance of the temperature measurement node from increasing, resulting in temperature error and misoperation. (4) The installation of the circulation pipeline should facilitate the elimination of gas in the pipeline. If the circulation pipeline leaks, stop the operation in time and use it after maintenance. (5) When it is found that the oil temperature is difficult to increase during the operation of the diesel burner of the electric heating heat transfer oil boiler, immediately check whether the pipeline is unblocked, whether the valve is wrong, whether the filter is blocked, and can only be used after use to eliminate it, and regularly Remove and clean the filter. (6) The user should customize detailed operating procedures and regular maintenance and overhaul of the system, and the operator should be very familiar with and master the operating points of the equipment. (7) Check the electric heating tube contacts, fuses, meters, meters and relays frequently. (8) Since the thermal oil boiler diesel burner is a precision instrument, it is strictly forbidden to transport or install it during severe vibration. Doing a good job in the maintenance of the diesel combustion engine of the electric heating heat transfer oil boiler can extend the service life of the equipment, maximize the work efficiency, and make the entire production process run safely and stably. (9) After the user replaces the heating element for a long time, the wiring must be reliable, and the heater should be leak tested to prevent the leakage of heat transfer oil, poor wire contact and fire accidents. The above is the maintenance method of the diesel burner of the electric heating heat transfer oil boiler. The operator should make the necessary preparations and investigations before operating the equipment. Irregular operation and use will cause serious damage to the heat transfer oil heating equipment. Matters needing attention 1. For the oil and gas heat carrier boiler diesel burner using heat transfer oil as the heat carrier, the system should be equipped with an expansion tank, a water storage tank, safety components, measuring instruments and control devices. 2. When the heat transfer oil is put into use, start the circulating oil pump during the running phase, and start ignition and heating after running for half an hour. When using for the first time, the temperature should rise slowly, about 20℃ per hour. When the temperature rises to 180~200℃, the temperature should be kept for a period of time before normal use. 3. When using, check carefully and strictly prevent the leakage of water, acid, alkali and low boiling point substances into the use system. The system should be equipped with a filter device to prevent all kinds of debris from entering and to ensure the purity of the oil. 4. After six months of use, oil analysis should be performed. If poor heat transfer or other abnormal conditions are found after long-term use, the oil should be analyzed, added or replaced according to the analysis results. Standard dosage: basic carbon must not be greater than 1.0%, acid value must not be greater than 0.5mgK(OH)/g, ignition point change must not be less than 20%, viscosity change must not be greater than 10%, and the new oil should be replaced. 5. In order to ensure the normal service life and heat conduction effect of heat transfer oil, it is strictly prohibited to use over temperature. The design and installation of the heating system of the heat-conducting oil boiler diesel burner shall strictly follow the design rules of the heat-conducting oil boiler light oil burner formulated by the relevant state departments to ensure the safe operation of the system. ! If you are interested in diesel combustion engines, please contact us for a quote!

  • BNL14/DSG Light Oil Burner

  • BNL300/350/600 P/FC diesel oil Burner

  • BNL75/100 P/FC Light Oil Burner

  • BNH40/60 G Heavy Oil Burner

  • BNL40/55 P/FC Diesel Light Oil Burner

  • BNG15/P gas burner

  • BNH20/30G Heavy Oil Burner

  • BNH 180/250/300 F Heavy Oil Burner

Inquiry For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.
Name:
Whatsapp:
* E-mail:
Product:
* Message:
Click on the button to verify