Home > News >

Notes on the operation of gas burners for stenter setting machines

2021-01-11 00:00


The burner of the stenter setting machine is a kind of setting equipment with superior performance and ideal treatment effect. The operation given to it also has certain requirements. For example, during the shutdown, the staff also have many points to pay attention to, so as not to cause adverse effects on the equipment. So, do you know what to pay attention to when the burner of the stenter setting machine is shut down? First of all, for the finished guide cloth, we need to place it on the operating table. Then, select the main control button of the burner of the stenter setting machine and adjust it to red, and at the same time, select '0' for the closed needle maintenance inlet button. When the cloth guide head reaches the cloth overfeeding roller, the equipment should be shut down and the cloth guide and the belt should be connected at the same time. Close the cooling cylinder tension motor to '0'. Then adjust the equipment to the interface of the heating system. At this time, it is better to adjust the heating temperature to one hundred and fifty degrees, and adjust the power of the circulation fan at the same time, so as to remove the residual moisture inside the burner of the stenter setting machine. After about thirty minutes, turn off the heating equipment, and at the same time ensure that the circulating fan and exhaust fan continue to work until the temperature in the oven drops below one hundred degrees. After these tasks are processed, we turn off the main switch of the power supply connected to the equipment. Then, the staff should clean the burner of the stenter setting machine, and should pay attention to keeping the working environment clean. During this process, the equipment should also be checked once to ensure that all parts are in good condition and there are no abnormal phenomena such as loosening. At the same time, it is necessary to ensure that the shutdown work is in place, and the work can only be closed after the inspection work is completed. The main points of attention about the operation of the burner of the stenter setting machine are shared here. It is recommended that all users and friends use the burner of the stenter setting machine in the future, the textile burner should be operated in accordance with the specified operating requirements to ensure the equipment Performance. I also hope that you can learn more about relevant knowledge so that it can be applied in work. If you are interested in low temperature burners, please contact us for a quote!

  • BNG35P/FC gas burner

  • BNG250/300/350P/FC Gas Burner

  • BNH350/600 F Heavy Oil Burner

  • BNG28P gas burners

  • BNH 180/250/300 F Heavy Oil Burner

  • BNG15/P gas burner

  • BNL14/DSG Light Oil Burner

  • BNL18/26/35 DSG Light Oil Burner

Inquiry For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.
Name:
Whatsapp:
* E-mail:
Product:
* Message:
Click on the button to verify