Regarding the operation of the burner equipment of the stenter setting machine, there are many problems that need attention. As users, we must not only inspect and maintain them in accordance with the specifications, but also master the correct operation methods and keep in mind the precautions. Only in this way can the operation of the burner equipment of the stenter setting machine be more stable and safe. In the process of operating the burner equipment of the stenter setting machine, if the full width needs to be adjusted, then the transmission parts of the machine should be rotated first to check whether it is normal. After confirming that it is normal, then adjust the full width to the required width, and at the same time adjust with the edge tracker, and adjust the overfeeding amount to a predetermined value. It should be noted that in order to ensure the good operation of the burner of the stenter setting machine, the staff need to regularly lubricate and maintain the width adjustment device, and carefully check whether the transmission system of the width adjustment device is normal. Under normal circumstances, within one month, or appropriate adjustments based on the use of the equipment, the width control system should be tested and adjusted. In addition, in the process of operating the burner of the stenter setting machine, the operation of the compressed air source also needs to be cautious. Firstly, check whether the air pressure of each part is normal, and should not be lower than the following requirements: Traction rolling car pressure: 0.35MPa; Tension stand: 0.25MPa; Two-roll rolling car: 0.5MPa; Cloth discharging device: 0.5MPa; Check the action of each pneumatic valve Whether it is normal or not, it can work only after conforming to it. In addition to the above operating precautions, the cloth threading operation of the burner of the stenter setting machine also needs to be treated. When guiding the cloth through the traction roller, the two-roller roller and the overfeeding roller on the cloth feeder, care should be taken to avoid injury to the hand from the roller. When the cloth is guided through the front storage rack, safety measures must be taken to prevent the operator from falling. ! If you are interested in low temperature burners, please contact us for a quote!