Home > News >

Choose the right biomass burner?

2021-01-18 00:00


To I believe that many people will encounter some problems after buying a burner. Foshan Lean Burner will share some failures of the control box. To Symptom: After the power is turned on, the burner cannot start, and the control box lights up the fault indicator. possible reason: To 1. The control box may be faulty. To 2. It may be that the motor of the burner cannot be started. The reason why the motor cannot start is not only the damage of the motor coil or capacitor, but also the bearing problem. It may also be caused by the outside air inlet of the burner. The fan is stuck. To 3. The motor may not move because the oil pump bearing is too tight. This may be caused by rusting of the oil pump caused by the oil. If you find this phenomenon, in addition to solving the problem of the fuel pump, you should also pay attention to the cleanliness of the fuel. If the fuel tank has a sewage outlet, clean the fuel tank. Please release dirt and moisture from the bottom of the water tank. If the fault lamp is lit due to some fault in the last operation of the burner, other fault causes can be considered. To Symptom: After the power is turned on, the burner cannot start, but the fault indicator on the control box does not light up. possible reason: To 1). Check the power fuse, check whether the thermostat temperature adjustment is appropriate. To 2). Check whether the control box has been firmly inserted into the junction box, and check whether the power wiring is loose. To 3). The control box may be faulty. To Gas burner shutdown operation: To There are two situations for shutdown: 1. When the temperature in the furnace reaches the set value, it will automatically shut down. At this time, the operator does not need any operation. When the furnace temperature is lower than the set value, the controller will automatically turn on. 2. When the personnel stops and the gear shifting stops, the operator should start the machine in the reverse order (1. First turn off the combustion control button, then turn off the fan button, 3. Finally turn off the power button)) to shut down. 3. When the shutdown time is long, the operator should close the gas pipeline valve to avoid gas leakage. To If you are interested in gas oil burners, please contact us for a quote!

  • BNH 75/100/120 F Heavy Oil Burner

  • BNG15/P gas burner

  • BNL120/180/250 P/FC Light Oil Burner

  • BNL14/DSG Light Oil Burner

  • BNH 180/250/300 F Heavy Oil Burner

  • BNH20/30G Heavy Oil Burner

  • BNH10G Heavy Oil Burner

  • BNG400FC/600FC Gas Burner

Inquiry For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.
Name:
Whatsapp:
* E-mail:
Product:
* Message:
Click on the button to verify