Home > News >

Can the diesel burner of the heat-conducting oil boiler replenish oil during operation?

2021-01-08


A specific type of boiler diesel burner heat conduction oil boiler diesel burner, I believe you will not think Strange or unfamiliar, because the related articles on the site have already introduced, you must continue to be familiar with and understand the common types of boiler diesel burners, so the following is not special, but this topic is still the main topic, but there is still no previous content, let everyone deepen the understanding Understanding of thermal oil boiler diesel burner. 1. What is the meaning of kw on the thermal oil boiler diesel burner? Thermal oil boiler diesel burner, its lowercase letter kw, from a professional point of view, it refers to the power unit of the boiler diesel burner, and its Chinese name is kilowatt. 1000KW = 1MW. In addition, the power unit of the boiler diesel burner can be converted, namely: 700kw = 0.7mw = 600,000 CAL. 2. The oil replenishment of the heat-conducting oil boiler diesel burner explains that the gas-phase furnace and the liquid-phase furnace are different in the oil-filled operation of the heat-conducting oil boiler diesel burner, so they should be handled separately. If it is a gas-phase furnace, usually 10 degrees below the oil, the design pressure is 1.2-1.5 times the working pressure. If it is a liquid furnace, the oil injection volume is less than 30 degrees, the design pressure is 1.05-1.2 times the working pressure, and the pressure difference between the inlet and outlet of the heat transfer oil of the liquid furnace should be greater than 0.15mpa. In addition, we also need to know that if the oil injection temperature in the heat transfer oil boiler diesel burner is too high, it will cause the boiler diesel burner flow to drop too quickly, aggravate the uneven heating of the heat transfer oil, and then accelerate the thermal degradation rate of the heat transfer oil. Lead to the coking of the thermal oil boiler diesel burner. 3. What are the important precautions for using thermal oil boiler diesel burner? Important precautions for using thermal oil boiler diesel burners are as follows: If the low-temperature thermal oil in the thermal oil boiler diesel burner, if its water content is too high, it will cause oil pressure fluctuations. After the pump is stopped, if the heat-conducting oil does not flow in the heating furnace, the temperature of the heat-conducting oil will increase. If it exceeds the limit that the oil can withstand, the service life of the heat-conducting oil will be shortened. In addition, if the heat transfer oil temperature is too high, it will also cause coking, carbonization and blockage of the heat transfer oil boiler diesel burner, which may cause danger or accident. Therefore, these problems should be avoided during the use of the thermal oil boiler diesel burner. Due to the leakage loss of heat transfer oil and the evaporation of low boiling point substances during operation, the amount of oil in the heat transfer system will gradually decrease. When the amount of oil in the system is insufficient, a certain amount of heat transfer oil needs to be added to ensure the normal operation of the system. For a heat transfer system that requires continuous operation, how to add heat transfer oil to the system under high temperature operating conditions? When the boiler diesel burner is operating normally, the cold heat transfer oil should be injected into the expansion water tank first, and then enter the main circulation loop of the system through the expansion pipe of the expansion water tank. Filling with oil in this way has the following two advantages: 1. Due to the volume expansion of the heat transfer oil, it avoids damage to the equipment system. During normal operation, the heat transfer oil in the system is under the condition of high temperature of the high temperature working oil. The temperature is directly added to the oil system, and the cold oil will be added to the high temperature mixing point hot oil. The cold oil will heat up in a short period of time, causing volume expansion, and damage to the equipment, resulting in leakage and safety accidents. 2. Avoid water or low boiling point substances directly entering the main circulation system. Because the supplement may contain water in oil or low boiling point, instead of dehydrating and degassing, adding cold oil directly to the high temperature circulation system can cause refueling in the water or rapid evaporation And low boiling point gasification, system pressure fluctuation affects the stable operation of the system, and in severe cases, it will cause heat conduction oil leakage and cause safety accidents. Matters needing attention 1. For the oil and gas heat carrier boiler diesel burner using heat transfer oil as the heat carrier, the system should be equipped with an expansion tank, a water storage tank, safety components, measuring instruments and control devices. 2. When the heat transfer oil is put into use, start the circulating oil pump during the running phase, and start ignition and heating after running for half an hour. When using for the first time, the temperature should rise slowly, about 20℃ per hour. When the temperature rises to 180~200℃, the temperature should be kept for a period of time before normal use. 3. When using, check carefully and strictly prevent the leakage of water, acid, alkali and low boiling point substances into the use system. The system should be equipped with a filter device to prevent all kinds of debris from entering and to ensure the purity of the oil. 4. After six months of use, oil analysis should be performed. If poor heat transfer or other abnormal conditions are found after long-term use, the oil should be analyzed, added or replaced according to the analysis results. Standard dosage: basic carbon must not be greater than 1.0%, acid value must not be greater than 0.5mgK(OH)/g, ignition point change must not be less than 20%, viscosity change must not be greater than 10%, and the new oil should be replaced. 5. In order to ensure the normal service life and heat conduction effect of heat transfer oil, it is strictly prohibited to use over temperature. The design and installation of the heating system of the heat-conducting oil boiler diesel burner shall strictly follow the design rules of the heat-conducting oil boiler diesel burner formulated by the relevant national departments to ensure the safe operation of the system. ! If you are interested in diesel combustion engines, please contact us for a quote!

  • Biomass burner particulate fuel selection requirements

  • Blue charcoal boiler burner made in China boiler burner

  • Sources and prevention of combustible gases in biomass burners

  • How to maintain and repair the burner for a short period of time

  • Technical advantages of biomass burners

  • Biomass burner Biomass burner technology is an advanced technology for manufacturing energy-saving an

  • Safety recommendations for burner installation and operation of stenter setting machine

  • What material does the biomass burner burn?

Inquiry For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.
Name:
Whatsapp:
* E-mail:
Product:
* Message: