- E-mail: [email protected]
- POffice Add:13th Floor, Building 16, National University Science Park,Zhengzhou,Henan,China
- Factory Add:No. 33 Xinhua Road,Xinmi,Henan,China
During the daily use of the burner equipment of the stenter setting machine, the user must not only pay attention to ensuring the rationality and standardization of the operation, At the same time, security issues must be taken into consideration. The so-called safety not only requires maintaining the safety of the burner equipment of the stenter setting machine, but also ensuring the safety of the staff. So, in actual work, what specific safety issues should be paid attention to? First of all, about the storage location of the burner equipment of the stenter setting machine. Under normal circumstances, the equipment should be placed in a relatively spacious surrounding, well-ventilated and non-corrosive gas environment. In addition, the storage location of the equipment should be flat and dry, and the concrete thickness of the foundation floor should not be less than 150 mm. At the same time, pay attention to ensure that the positions of the needle plates on both sides are level and symmetric, and no position deviation is allowed. Secondly, in the process of installing the burner equipment of the stenter setting machine, it is necessary to ensure that the track does not contain any impurities or other phenomena that hinder the normal operation of the chain. In the process of installing the driving roller, cloth guide roller and doffing roller, the low-temperature burner needs to calibrate the parallelism between the rollers. Third, before turning on the burner equipment of the stenter setting machine, be sure to check the current environmental conditions. Remember, no other personnel are allowed to stand near the equipment; no maintenance and maintenance personnel are working. In addition, pay attention to check and ensure that the temperature of the constant temperature room of the electric control box should be within the specified range. If there is dust and other debris accumulated in the electric control box, it should be cleaned up in time. In addition, before starting the temperature control program of the burner equipment of the stenter setting machine, the staff should pay attention to check the various transmission parts of the equipment in advance to ensure flexible operation. Then adjust the full width to the required width, and adjust it with the selvedge tracker, and also adjust the overfeed amount to a predetermined value. If you are interested in low temperature burners, please contact us for a quote!