- E-mail: [email protected]
- POffice Add:13th Floor, Building 16, National University Science Park,Zhengzhou,Henan,China
- Factory Add:No. 33 Xinhua Road,Xinmi,Henan,China
To Burners are also called burners. According to the fuel, they can be pided into oil burners, gas burners, and biomass burners; according to the objects of use, they can be pided into kiln burners and boiler burners; according to application fields, they can be pided into industrial burners, Civil burners and special burners. Among them, oil burners are pided into light oil (such as diesel) and heavy oil burners (such as waste oil). Gas burners are pided into natural gas burners, liquefied gas burners, city gas burners, biogas burners, etc., biomass burners It uses biomass particles to burn dust-free and pollution-free. The burner we usually call refers to the boiler burner. To Matters needing attention when using the burner: When connecting the peripheral circuit, please follow the control system wiring diagram when realizing automatic control of the boiler temperature, pressure, and water level. The oil suction pipe should not be close to the bottom of the fuel tank, and a distance of 80-120mm should be maintained. The burner should be turned off before filling the fuel tank, the fuel can be filled into the fuel tank after being filtered, and the fuel can only be restarted after 20 minutes of filling. The oil system must not leak oil or gas. Check the fuel tank for sufficient fuel before starting the burner. The size of the damper should match the nozzle specification. When the burner is in use, because the boiler equipped with the burner is inconsistent with the boiler used for debugging when the burner leaves the factory, it is generally necessary to adjust the air door appropriately, and sometimes it is necessary to replace the nozzle of the appropriate specification and injection angle. To The ambient temperature of the burner should not exceed 70℃, otherwise measures should be taken to cool down and heat insulation. When used in colder areas, proper insulation measures should be taken for the oil storage device and the oil supply and return pipeline system to prevent the oil circuit from being blocked due to freezing. At the same time, the control circuit of the burner must not be exposed to moisture or high temperature. Turn off the burner when cleaning the chimney. The motor should be protected from moisture and avoid using it in a humid environment. The burner should be balanced during installation, and it should be used horizontally or vertically, and avoid tilting. When it is not convenient to directly operate the burner, an external control switch and electrical protection device should be connected. Frequently check whether the connection of the burner and each component is firm, whether it is loose, and whether the position is changed. When the burner is started, strictly prevent the sudden flame from hurting people and destroying objects. To The light diesel oil used must be clean, please pay attention to regularly clean the oil tank and oil filter. Under normal use, change the oil nozzle once a year, and the elastic coupling and the rubber parts on the coupling once a year and a half. Foreign objects are strictly prohibited from entering the air duct. The use site of the burner should be far away from flammable and explosive materials, and fire extinguishing equipment should be provided. Adjust the oil pressure appropriately according to the indicated value of the oil pressure. Regularly check the combustion tube, impeller, flame detector and ignition electrode to remove oil and carbon deposits. Especially the flame detector should be kept clean and not wet. Always cut off the power when maintaining the burner. To If you are interested in gas oil burners, please contact us for a quote!
Previous: Pre:What is the safety ignition problem of the burner