- E-mail: [email protected]
- POffice Add:13th Floor, Building 16, National University Science Park,Zhengzhou,Henan,China
- Factory Add:No. 33 Xinhua Road,Xinmi,Henan,China
To The burner is installed on the stove. When burning and debugging, if there is black smoke, gradually open the big damper; if there is white smoke (water vapor), gradually close the small damper; the damper is as small as the smokeless state is the best when the burner burns normally. After working for a few minutes, turn off the power and turn it on again after stopping for a few minutes to observe whether the ignition and combustion are normal. If there is no abnormal phenomenon after repeated several times, the adjustment of the burner is finished. In the commissioning work, gas must be serious, safe and efficient. If the alarm light is on after starting the burner, you need to wait at least 20 seconds before pressing the reset button again to restart. If the flame length is very short and the color is red, then close the adjusting damper until the flame is slightly yellow and faintly dazzling, its ignition power is strong and the flame length is moderate. If the color of the flame is red, its ignition strength is poor, and the fire speed is low, at this time, adjust the damper to continue to open. Matters needing attention until the flame is slightly yellow and faintly dazzling, its ignition power is strong and the fire speed is strong Moderate is enough. Before the burner is started, the matters to be noted are first to slightly open the adjusting damper below the body (opening is 1/3 of the full opening), and then start the machine, the ignition power of the flame and the speed of the jet flame, etc. When the burner fails to re-ignite continuously, the burner should be shut down to check whether the gas supply system of the Belden burner is normal and the circuit connection is correct. The burner can be restarted after the failure is removed before the burner is used. It is strictly forbidden to knock or rub the gas supply pipeline with a wrench or a metal rod to avoid static electricity or sparks and gas explosions. It is strictly forbidden to smoke, weld, cut and other illegal operations in the air supply valve block or pipe flange surface, etc. It is strictly prohibited to conduct any open flame test near the pipeline, valve block and pressure regulating valve to avoid major accidents. Test whether there is fuel in the gas supply pipeline, usually with a gas low pressure meter. In the gas supply pipeline, it has been evacuated, but there are residual gas or liquid droplets on the pipe wall. If it encounters static sparks and open flames, it will also cause combustion and explosion. When the air supply pipeline has been ventilated and the valve block needs to be disassembled when there is a fault, the front main valve of the valve block must be cut off first, and then the valve block can be disassembled and repaired. To If you are interested in gas oil burners, please contact us for a quote!