Home > News >

What are the potential safety hazards of gas heat conduction oil boiler diesel burner?

2021-01-08


The gas heat conduction oil boiler diesel burner belongs to the special heat generating mechanical equipment, which will generate a large amount of heat during operation. Heat, once in contact with the human body, the internal heating of the heat transfer oil will cause serious burns to the body. The heat transfer oil boiler diesel combustion engine gas is also a dangerous mechanical equipment, and it is likely to be a little careless. If an accident occurs, once the accident occurs in people’s lives Property security is a big threat. As a company, it is necessary to avoid similar situations, strive to strengthen the training and management of employees, in the long run, to better ensure the safety of the factory. The safety of the gas heat conduction oil boiler diesel burner mainly includes two points, one is the safety of related equipment, and the other is the safety knowledge training of operators. The gas heat conduction oil boiler diesel combustion engine is checked before use. The purpose of the inspection is to ensure that it can operate normally without any failure. The preheating is also used to make the mechanical equipment run for a period of time. If there is no problem in all the functions of the inspection system, When using the official, for example, is the temperature and pressure large or small, the valve works normally, etc. When all these issues are checked, most of our work has been completed, and the rest is left to the factory operators. Factory operators must wear gloves to work. Qualified companies can provide them with work clothes, making them very convenient at work without any safety issues caused by other factors. Because the temperature of the heat transfer oil in the heat transfer oil boiler diesel burner is very high, it will cause serious burns to the human body once it comes in contact with the human body. Many vivid examples tell us not to touch the liquid, let alone stay in the place of the heat transfer oil boiler diesel burner. , Stay away from them as much as possible, after all, life is the most precious to us. In addition to some safety knowledge, the factory should also keep some temporary first aid kits so that we can deal with some minor problems urgently so as not to delay our own rescue time. The combustion gas of the heat-conducting oil boiler diesel burner is like a large fuel tank, its high temperature is inside, it will generate a lot of water and steam during operation, we should ensure that its vents and vents are unobstructed and never blocked Because it easily leads to higher internal pressure, there is a danger of explosion. Once it explodes, the consequences are unimaginable. Check before starting 1. Whether the heating furnace and its surrounding environment are clean and free of debris, check whether the furnace body, burner, controller, fire hole and smoke (chimney) passage are normal; 2. Countercurrent process equipment and process, check the expansion water tank oil Whether the level is higher than 1/4 to 1/2 level, whether the thermometer and pressure gauge are normal; 3. Connect the heating furnace control cabinet power supply, check whether the voltage is normal, check whether the indicator light and all display instruments are normal; 4. Adjust the main reduction Pressure valve and secondary pressure reducing valve control the pressure at 0.005mpa. Start 1. Start the heat transfer oil circulating pump (standby, according to the pump operation rules), and keep the pressure stable for about 0.5 hours after starting the pump; 2. Press the burner start button and observe whether the flame in the furnace is burning normally. If it does not ignite, please start the burner again after troubleshooting. Furnace operation 1, normal stop (1) Gradually reduce the temperature, turn off the burner, and stop burning; (2) When the hot oil temperature drops below 70°C, stop the operation of the hot oil circulating pump (see the operation rules of the water pump); ( 3) Turn off the main power and make a record of switching. 2. Emergency stop. If the furnace is shut down due to an emergency, the burner should be shut down quickly, and the burner should be moved along the burner reaming axis to form a natural ventilation state between the furnace and the chimney, accumulate heat and distribute it in the furnace, so that The heat transfer oil cools naturally to prevent overheating. Matters needing attention During the inspection, please pay attention to check whether there is leakage around the diesel burner of the thermal oil boiler. There should be sufficient petroleum and electrical fire fighting equipment nearby. Water should not be used as an extinguishing agent. Matters needing attention 1. For the oil and gas heat carrier boiler diesel burner using heat transfer oil as the heat carrier, the system should be equipped with an expansion tank, a water storage tank, safety components, measuring instruments and control devices. 2. When the heat transfer oil is put into use, start the circulating oil pump during the running phase, and start ignition and heating after running for half an hour. When using for the first time, the temperature should rise slowly, about 20℃ per hour. When the temperature rises to 180~200℃, the temperature should be kept for a period of time before normal use. 3. When using, check carefully and strictly prevent the leakage of water, acid, alkali and low boiling point substances into the use system. The system should be equipped with a filter device to prevent all kinds of debris from entering and to ensure the purity of the oil. 4. After six months of use, oil analysis should be performed. If poor heat transfer or other abnormal conditions are found after long-term use, the oil should be analyzed, added or replaced according to the analysis results. Standard dosage: basic carbon must not be greater than 1.0%, acid value must not be greater than 0.5mgK(OH)/g, ignition point change must not be less than 20%, viscosity change must not be greater than 10%, and the new oil should be replaced. 5. In order to ensure the normal service life and heat conduction effect of heat transfer oil, it is strictly prohibited to use over temperature. The design and installation of the heating system of the heat-conducting oil boiler diesel burner shall strictly follow the design rules of the heat-conducting oil boiler diesel burner formulated by the relevant national departments to ensure the safe operation of the system. Equipment risk analysis 1, general chaos, employee injury, minor economic loss. 2. The staff suffered severe interference, minor injuries, severe casualties, and heavy economic losses. 3. Major, especially major chaos, group injuries, especially major economic losses. ! If you are interested in diesel combustion engines, please contact us for a quote!

  • Technical advantages of biomass burners

  • Biomass burner particulate fuel selection requirements

  • Sources and prevention of combustible gases in biomass burners

  • Diesel Burner Galvanizing Furnace Manufacturer

  • Pay attention to environmental protection in the use of biomass burners

  • How to maintain and repair the burner for a short period of time

  • Blue charcoal boiler burner made in China boiler burner

  • Biomass burner Biomass burner technology is an advanced technology for manufacturing energy-saving an

Inquiry For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.
Name:
Whatsapp:
* E-mail:
Product:
* Message: